Skip to main content
AEM

Renaissance has been designing and building circulators and isolators to meet the rigorous demands of both commercial and defense satellite applications for decades. All of our products are designed and tested to our unique customer requirements. This has expanded to include may other passive elements such as power dividers, filters, mixers, and more.

Renaissance often utilizes a standardized screening process, summarized below. This can be adapted to your unique requirements as needed.

Acceptance Testing

Test

Sampling Basis

Condition

Pre-Cap Inspection

100%

Renaissance and HXI Inspection Procedure

Stabilization Bake

100%

MIL-STD-883, Method 1008, Condition A or B, +90C for 48 hours minimum, prior to package seal

External Visual and Mechanical Examination

100%

Parts shall be examined at 10X magnification

Initial Electrical Measurements

100%

Tested at +25C for all parameters

Thermal Shock

100%

MIL-STD-202, Method 107, temperature limits shall be -50C to +90C, 10 cycles

Interim Electrical Measurements

100%

Testing performed at three temperatures, -40C, +25C and +85C for all parameters

Mechanical Shock

100%

MIL-STD-202, Method 213. Pulse shall be half-sine and the peak acceleration shall be 1500g. The duration of the pulse shall be 0.3ms. 3 shocks on each axis

Vibration: Random

100%

MIL-STD-202, Method 214, Acceptance Parameters (see Random Vibration Table, shown below)

Final Electrical Measurements

100%

Testing performed at three temperatures, -40C, +25C and +85C for all parameters

Vibration Table

36 gms overall

10 to 50 Hz: +3dG/octave

50 to 100Hz: 0.8 g^2/Hz

1000 to 2000 Hz: -3dB/octave

Duration 60 second/axis

Qualification Testing

Test

MIL-STD-202 (unless otherwise specified) Condition

Initial Electrical

Tested at +25C for all parameters

Thermal Shock

Method 107, temperature limits shall be -50C to +90C, 25 cycles

Vibration: Random

MIL-STD-202, Method 214, Qualification Parameters See Random Vibration Table below.

Final Electrical

Testing performed at three temperatures, -40C, +25C and +85C for all parameters

Random Vibration Levels

All Axes (X, Y, Z Axes)

Frequency (Hz)

Acceleration PSD or Slope Level

Acceptance Parameters

Qualification Parameters

20

0.013 g2/Hz

0.026 g2/Hz

20-50

+ 6.0 dB/octave

+ 6.0 dB/octave

50-800

0.08 g2/Hz

0.16 g2/Hz

800-2000

-6.0 dB/octave

-6.0 dB/octave

2000

0.013g2/Hz

0.026g2/Hz

Overall

10.0 grams

14.1 grams

Duration

60 seconds/axis

120 seconds/axis